| CLT Series
Hard-Wired / Wall-Mounted Units |
|
|
CLT Series line conditioners
protect computers, telecommunications equipment and other sensitive
electronic devices from the damage and distruptions caused by power
supply fluctuation.
CLT Series line conditioners
protect against anything short of a complete blackout, including
routine over- and under-voltage conditions, brownouts, spikes, surges,
sags, and noise.
|
|
 |
 |
| |
 |
CLT
Specs |
|
 |
|
- Built-in Surge and Noise Protection
- CLT plug-in units include solid state, multi-stage surge
suppression for lowest let-through of any power conditioner;
CLT hard-wired units include single stage surge protection.
- Reliable Ferroresonant Technology
- No moving parts; long, dependable life
- Bi-directional Filtering
- 3% Voltage Regulation
- Excellent Isolation and Noise Rejection
- Harmonic Contol
- Complete Power Conditioning
- Guards against interruptions of up to 3 millisenconds
- Continuous Regulation
- Compensates for brownouts and overvoltages
|
- Wider Input Voltage Range
- Super Isolation and Tight Regulation
- Protects sensitive microprocessors
- Multiple VA Ratings
- Accommodate desktop to mid-size microprocessor-based systems
- Ferroresonant Technology
- Reliable, maintenance-free; no moving parts
- Low Noise
- Enclosure design minimizes audible noise
- Easy to Install
- Floor or Wall-mounted CLT units are hard-wired
- Warranty
- 50 Hz Units Available
- UL Listed
|
|
|
 |
|
| Power Ratings |
2.1 / 3.1 / 5.0 / 60 kVA |
| Lightning and Surge Protection |
ANSI / IEEE C62.41. Categories A and
B |
| Noise (RF) Isolation |
120 dB Common Mode; 60 dB Normal Mode |
| Input Voltage |
+10/-20% (depends on model) |
| Output Voltage Regulation |
±3% |
| Isolation |
Complete from line; output neutral
bonded to ground |
| Output Wave Form |
Sine Wave: 3% THD |
| Output Overload Protection |
Inherent with refforesonant technology
- current limiting |
| Response Time |
Instantaneous (no measurable delay) |
| Line Interruption |
Full outout voltage maintained for
3 milliseconds |
| Short Circuit Protection |
Approximately 200% of load current;
no damage will occur |
| Safety |
UL listed |
| Warranty |
5 years |
| Controls |
None required |
|
|
 |
|
| Model Number |
Capacity (VA/W) |
Dimensions (HxWxD)
(inches) |
Input Voltage |
Output Voltage |
Shipping Weight
(lbs) |
| Wall Mounted Models |
| CLT-0140-GTB |
140/140 |
4-3/8 x 6 x 8½ |
120/208/240/480 |
120/208/240 |
15 |
| CLT-0250-GTB |
250/250 |
4-3/8 x 6 x 9-5/8 |
120/208/240/480 |
120/208/240 |
23 |
| CLT-0500-GTB |
500/500 |
6½ x 6¼ x 12¼ |
120/208/240/480 |
120/208/240 |
30 |
| CLT-0750-GTB |
750/750 |
6½ x 6¼ x 13¼ |
120/208/240/480 |
120/208/240 |
41 |
| CLT-1000-GTB |
1000/1000 |
6½ x 6¼ x 14-3/16 |
120/208/240/480 |
120/208/240 |
47 |
| CLT-1500-GTB |
1500/1500 |
10 x 9-1/3 x 17½ |
120/208/240/480 |
120/208/240 |
79 |
| CLT-2000-GTB |
2000/2000 |
10 x 9-1/3 x 18¼ |
120/208/240/480 |
120/208/240 |
96 |
| CLT-3000-GTB |
3000/3000 |
10 x 9-1/3 x 20 |
120/208/240/480 |
120/208/240 |
132 |
| CLT-5000-GTW |
5000/5000 |
14 x 14½ x 27 |
120/208/240/480 |
120/208/240 |
254 |
| CLT-7500-RTW |
7500/7500 |
14 x 14½ x 28¼ |
208/240/480 |
120/208/240 |
318 |
| CLT-1001-RTW |
10,000/10,000 |
14 x 14½ x 29¼ |
208/240/480 |
120/208/240 |
390 |
| CLT-1501-RTW |
15,000/15,000 |
14 x 14½ x 28¼ |
208/240/480 |
120/208/240 |
648 |
| Floor Mounted Models |
| CLT-5000-GTO |
5000/5000 |
40 x 19 x 21¾ |
120/208/240/480 |
120/208/240 |
335 |
| CLT-7500-RTO |
7500/7500 |
40 x 19 x 21¾ |
208/240/480 |
120/208/240 |
398 |
| CLT-1001-RTO |
10,000/10,000 |
40 x 19 x 21¾ |
208/240/480 |
120/208/240 |
458 |
| CLT-1501-RTO |
15,000/15,000 |
40 x 19 x 21¾ |
208/240/480 |
120/208/240 |
612 |
|
|
| Custom
Applications - Contact MajorPower.Com |
| |