ZoneMaster 300

The ZoneMaster 300 is engineered to protect critical electronic systems from severe transient environments, providing decades of uninterrupted surge protection. A tested surge capacity of 300,000A assures a high level of protection from even the most severe lightning strikes.

ZoneMaster 300 Brochure Download
  ZoneMaster 300 Specs ZoneMaster 300 Specs

  • Up to 300,000 Amp Maximum Surge Current Protection
    • Provides unmatches protection against catastrophic surges. ratingbased on the withstand and survival current of the unit, not the sum of the components.
  • Integrated Diagnostics
    • Each module provides visual indications of its operating status or miswiring
  • Neutral-to-Ground Leakage Indicators
  • Boldted Connections Securely Attach Modules Into Surge Current path
    • No plug-in modules
  • Large Surge Return Plate
    • Both electrical and mechanical indicators display operational readiness of unit.
  • Remote Monitoring Unit Available
  • Large Surge Return Plate
    • Protection modules are mounted on a surge return plate that accurately cancels the electromagnetic field during surge events.
  • Fire Resistant Lightweight plastic Enclosure
    • NEMA 1, 2, 2S, 4, 4X, and 13 rated. UL94-5V Flame class.
  • Clear Unit Cover
    • Allows user to monitor protection status without opening the unit.
  • Dual Short Circuit and Thermal Fusing
  • Maximum Operating Voltage
    • 25% above nominal service voltage
  • Operating Environment
    • -40° to +85°C
  • Ten-Year Product Warranty
  • UL CSA Approved

 
Maximum Continuous Operating Voltage 25% above nominal
Remote Indication Contacts NO/NC, rate 125 VAC, 2A
Module Diagnostics Green LED mechanical (fuse link operated) flag red LED
Standard Fuse Disconnect 600 VAC; 200,000A RMS Symmetrical rating; 200,000 AIC fusing
Redundant Protection Stages In All Modes Each molde contains dual independant redundant protection circuits
Enclosure NEMA 1, 2, 3, 3S, 4, 4X, 12, and 13. Transparent cover for maximum visibility and safety.
Operating Environment -40°C to 85°C, relative humidity (non-condensing)
Construction Ultra low impedance assembly. Modules are bolted to a corrosion resistant, tin plated coper bus bar. Non plug-on modules in the surge path.
Terminal Lugs #2 AWG max wire size
Mounting 0.31" diameter holes (16.75" x 12.00")
(enclosure can be easily drilled for cable access)
Module Replacement Remove two bolts, unplug remote indication connector and remove module. Estimated replacement time: 2 minutes.
Module Dimensions 1.25" x 5.3" x 2.5" (3.2cm x 13.5cm x 6.4cm)
Dimensions 16" x 14" x 7" (42cm x 37cm x 18cm)
Weight Approximately 20 lbs

Models Electrical Service Maximum Surge Current UL 1449 Clamping Dimensions Service Voltage
ZHC120T-E 150,000A   150,000A 75,000A 120V/240V
250 125,000A 125,000A 250,000A 75,000A 120V/208V 3Ø 4W
300 150,000A 150,000A 300,000A 75,000A 120V/240V 3Ø 4WD
450 300,000A 150,000A 450,000A 75,000A 77V/480V 3Ø 4WYE
600 300,000A 300,000A 600,000A 75,000A 220V/380V 3Ø 4 Wire WYE
240V/415V 3Ø 4 Wire WYE