Product List | Order | Contact Us

Search:  
 
Tel: 514.369.4919 Fax: 514.369.4817

  Home > Surge Protection > ZoneMaster150

Email this page
ZoneMaster150

ZoneMaster150 is designed to withstand the severe transient environment at large service entrance panels. 150,000A of independently tested surge capacity assures a high level of protection from severe lightning strikes

ZoneMaster 150 Brochure Download
  ZoneMaster 150 Specs ZoneMaster 150 Specs

  • 150,000A surge capacity per phase
  • Replaceable modules
  • Comprehensive diagnostics
  • Remote indication capabilities
  • NO/NC dry contacts for remote monitoring
  • NEMA 1, 2, 3, 3S, 4, 4X, 12, 13 rated enclosure
  • Protection redundancy ensures reliability for critical lines
  • Low impedance construction
  • High N/G voltage warning
  • Dual thermal and short circuit fusing
  • Color coded modules
  • Ten Year - No fuss warranty
  • Patented Technology (No. 5,311,393)

Maximum Continuous Operating Voltage 25% above nominal
Remote Indication Contacts NO/NC, rate 125 VAC, 2A
Module Diagnostics Green LED mechanical (fuse link operated) flag red LED
Standard Fuse Disconnect 600 VAC; 200,000A RMS Symmetrical rating; 200,000 AIC fusing
Redundant Protection Stages In All Modes Each molde contains dual independant redundant protection circuits
Enclosure NEMA 1, 2, 3, 3S, 4, 4X, 12, and 13. Transparent cover for maximum visibility and safety.
Operating Environment -40°C to 85°C, relative humidity (non-condensing)
Construction Ultra low impedance assembly. Modules are bolted to a corrosion resistant, tin plated coper bus bar. Non plug-on modules in the surge path.
Terminal Lugs #2 AWG max wire size
Mounting 0.31" diameter holes (16.75" x 12.00")
(enclosure can be easily drilled for cable access)
Module Replacement Remove two bolts, unplug remote indication connector and remove module. Estimated replacement time: 2 minutes.
Module Dimensions 1.25" x 5.3" x 2.5" (3.2cm x 13.5cm x 6.4cm)
Dimensions 16" x 14" x 7" (42cm x 37cm x 18cm)
Weight Approximately 20 lbs

Models Service Voltage UL 1449 Cat B3:3kA Cat C3:10kA
11200 120V/240V Split Ø 3 Wire 400 Volts 350V 446V
11201 120V/208V 3Ø 4 Wire WYE 400 Volts 350V 446V
11202 120V/240V 3Ø 4 Wire Delta 400 Volts 350V 446V
11203 240V 3Ø 3 Wire Delta 800 Volts 760V 886V
11204 277V/480V 3Ø 4 Wire WYE 800 Volts 760V 886V
11206 480V 3Ø 3 Wire Delta 1500 Volts 1480V 1680V
11207 220V/380V 3Ø 4 Wire WYE 800 Volts 760V 886V
11208 240V/415V 3Ø 4 Wire WYE 800 Volts 760V 886V

Custom Surge Applications - Contact MajorPower.Com
 