| Input |
| Voltage |
115/230 VAC ±15%; 47 - 63Hz;
Auto-ranging available |
| Protection |
Thermal Fuse; Inrush current limiting |
| Isolation |
2250 VDC input to chassis; 4300 VDC input to output, 8 mm spacing;
500 VDC output to chassis |
| Output |
| Voltages |
12 VDC/25 Amps, 24 VDC/12.5 Amps, 48 VDC/6.25 Amps, 125 VDC/2.4 Amps standard |
| Line/Load & Cross Regulation |
±1% combined |
| Overvoltage Protection |
Double regulator loop |
| Overload Protection |
Current limiting with short circuit protection.
Self-resetting thermostat for thermal protection
|
| Efficiency |
Min 80% at full load |
| RFI Suppression |
Meets requirements for FCC Class A and EN 55022 Class A conducted emissions |
| Ripple/Noise |
Better than 1% of output voltage peak to peak or 0.2% RMS of output voltage (20 Hz BW) |
| Hold Up Time |
Minimum 10 ms at full load for 5% drop of output voltage |
| Mechanical |
| Operating Temperature |
0 to +50°C with convection cooling, Extended temperature range available |
| Temperature Drift |
0.03% per °C over operating temperature range |
| Dimensions |
F Package: 11.4 x 5.2 x 2.525
Plug-in module: 4U x 304mm x 16HP
Shelf: 4U x 19 or 23 x 15 deep
|
| Connections |
Screw type terminal block. H15 DIN connector for the modules Copper studs for the shelf. For other connectors please consult factory |
| Warranty
|
Twelve months subject to application within good engineering practice
|
| Approvals |
Full compliance to IEC950, CSA 22-2-950 and UL 1950 Please contact MajorPower.Com for approval status for the requested input/output configuration |