Product List | Order | Contact Us

Search:  
 
Tel: 514.369.4919 Fax: 514.369.4817

  Home > Powerware > 9170+

Email this page
Powerware 9170+ UPS

The 9170+ enables customers to "build" a power solution specific to their needs, with an expandable level of redundancy and increased run times through plug-andplay 3 kVA UPS and battery modules. The 9170+ can be configured to fit three-, six-, nine- or twelve-slot enclosures, and is available for rack-mount applications.

The 9170+ also features a new "power-saver" high efficiency mode, a user-selectable feature that increases unit efficiency from 88% in normal operating mode to 97% in Power Saver mode. The combination of its low initial investment, double conversion online technology, ABM, and new highefficiency power-saver mode, means you never have to compromise reliability for efficiency. Unique to the 9170+ is its global deployment capability. By using a high frequency design, housing both logic and power in the power module, andoffering a single cabinet design, distributors and purchasing departments around the world will have fewer system components to contend with, regardless of where the system is deployed.

9170+ UPS9170+ UPS

9170+ UPS Features
  • Maximum Performance
    • The lowest overall cost of ownership is a direct result of the low initial investment, higher operating efficiencies and programmable high efficiency
    • A UPS solution that is as easy to install and operate as a PC. Universal components fit in any order in any slot without affecting the operation of the system or its protection of the critical load
    • Featuring user-friendly LCD display and two internal communication slots, which accept a wide variety of connectivity devices and the new SNMP/Web adapter card
    • Lightweight, high-performance power and battery modules weigh under 30 lbs. for easy service and hot swapping
  • Maximum Reliability
    • N+X power and logic redundancy eliminates single point-of-failure providing highest reliability and availability
    • Redundant modularity virtually eliminates downtime and enhances serviceability
    • ABM doubles battery service life
  • Maximum Availability
    • Double conversion online technology is universally recognized as providing the highest availability in an internetcentric global marketplace
    • Provides protection against power surges, spikes, sags, line noise, and lightning
  • Maximum Service Plans
    • Powerware Gold Plan Plus Enhance and extend your standard UPS warranty with added assurance of knowing your UPS is installed and operated properly from the start
    • Comprehensive coverage for the entire UPS
    • On-site start-up by authorized Powerware Representative
    • Replacement UPS or module delivered to your locations
    • Original UPS or module picked up from your locations
  • Maximum Flexibility
    • Modular design delivers scalable flexible solutions to constantly changing equipment requirements
    • Easily expanded by installing additional power, charger, or battery modules to support additional critical applications and devices
    • Internal Options: galvanic isolation, line cord, receptacles, communications
    • External options: Rack-mount kit, casters (standard on 9- and 12-slot enclosures), extended runtime battery cabinets (housing up to 8 hours of additional runtime), wall-mounted maintenance bypass cabinets

9170+ UPS Specifications
General
Topology True online, double-conversion
Diagnostics Full system self-test on power up
UPS Bypass Automatic on overload or UPS failure
Environmental And Safety
Safety Markings UL, CUL
EMC Markings FCC class A
Surge Suppression IEEE/ANSI C62.41
Audible Noise <50dBA
Ambient Operating 0 to 40ºC (32 to 104ºF)
Storage Temperature -20 to 40ºC (60ºC w/o batt); -4 to 104ºF (140º F w/o batt)
Relative Humidity 5% to 95%, non-condensing
REPO Port Meets NEC code 645-11 intent and UL requirements
Battery
Internal Battery Type Sealed, lead-acid; maintenance free
Battery Replacement Hot-swappable
Recharge Time <4 hours standard
Electrical Input
Voltage 208-240V or 200/100, 208/120, 220/110,240/120 Vac
Voltage Range 176-276V
Input Power Factor .98
Frequency 50/60 Hz (±3 Hz)
Electrical Output
On Utility Voltage Regulation ±3% of nominal
On Battery Voltage Regulation ±3% of nominal
Efficiency 88% normal operation; 97% High performance (optional programmable)
Frequency Regulation ±3 Hz online; ±0.1 Hz on battery
Communications
LCD Display 4 x 20 character backlit display, programmable
Language Support English, French, Spanish and German
Communication ports RS232, (DB9) (std)
Communication slots 2 Slots (standard)
SNMP capability SNMP/Web enabled card options
Contact Closures Relay Card option
Emergency Power off (EPO) Input for external EPO

9170+ UPS Model Selection Guide
Model
Number
Power
Rating
Input
Connection
Output
Connection
Dimensions
HxWxD (in/cm)
Weight
(lb/kg)
UPS Cabinet Enclosures with Hardwire Input and Output Connections
9170+ 3 Slot 3 KVA Hardwired Hardwired 17.8 x 17.0 x 25.5/
45.0 x 43.0 x 65.0
66.0/30.0
9170+ 6 Slot 3 to 9kVA Hardwired Hardwired 31.5 x 17.0 x 25.0/
80.0 x 43.0 x 65.0
103.0/47.0
9170+ 9 Slot 3 to 18kVA Hardwired Hardwired 47.0 x 24.0 x 28.5/
119.5 x 61.0 x 72.5
158.0/72.0
9170+ 12 Slot 3 to 18kVA Hardwired Hardwired 60.8 x 24.0 x 28.5/
154.0 x 61.0 x 72.5
196.0/89.0
Battery Cabinet Enclosures
6 Slot Battery Cabinet - DC Interconnect Option
ASY-0525 Required
- 17.8 x 17.0 x 25.5/
45.0 x 43.0 x 65.0
93.0/42.2
9 Slot Battery Cabinet - DC Interconnect Option
ASY-0525 Required
- 47.0 x 24.0 x 28.5/
119.5 x 61.0 x 72.5
148.0/67.1
12 Slot Battery Cabinet - DC Interconnect Option
ASY-0525 Required
- 60.8 x 24.0 x 28.5/
154.0 x 61.0 x 72.5
186.0/84.4
Available Modules
Split Phase Power Module 3 kVA/2.5kw - - 4.2 x 14.1 x 15.3/
10.6 x 35.8 x 38.9
17.0/7.7
Universal Power Module 3 kVA/2.5kw - - 4.2 x 14.1 x 15.3/
10.6 x 35.8 x 38.9
17.0/7.7
Battery Module - - - 4.2 x 7.0 x 14.8/
10.6 x 17.8 x 37.6
30.0/13.6
20 Amp Charger Module 3kVA - - 4.2 x 14.1 x 15.3/
10.6 x 35.8 x 38.9
17.0/7.7
Notes: 50/60 Hz automatic frequency selection. Input/Output voltages 208-240 V or100/200,120/208, 127/220, 110/220 and 120/240 V. Split phase power Module offer both high and low output voltage. Universal Power Module offers only high output voltage. (3) and (6) slot enclosure dimensions include caster kit.

9170+ UPS Battery Runtime
Runtime Chart (full load / half load) Split-Phase Module ASY-0673
Load (VA) Number of Strings (2 battery modules per string)
  1 String 2 String 3 String 4 String 5 String 6 String 7 String 8 String
3kVA 6.5/16 16/40 27.5/67.5 40/98 53.5/132 67.5/167 83/204 98/242
6kVA   6.5/16 11/27.5 16/40 21.5/53.5 27.5/68 33.5/83 40/98
9kVA     65/16 9.5/23.5 13/31.5 16/40 20/49 23.5/58
12kVA       6.5/16 9/21.5 11/27.5 13.5/33.5 16/40
15kVA         6.5/16 8/20.5 10/25 12/30
18kVA           6.5/16 8/20 9.5/23.5
  9 String 10 String 11 String 12 String 13 String 14 String 15 String 16 String
3kVA 15/283 132.324 149/365 167/408 185/456 204/501 223/549 242/595
6kVA 46.5/15 53.5/132 60.5/149 575/167 75/85 83/204 90/223 98/242
9kVA 27.5/67.5 31.5/78 35.5/88 40/98 44/109 49/120 535/132 58/143
12kVA 19/46.5 21.5/53.5 24.5/60.5 27.5/68 30.5/75 33.5/83 37/90 40/98
15kVA 14/35 16/40 18.5/45 20.5/50.5 23/56 25/62 27.5/67.5 30/73.5
18kVA 11/27.5 18/44 14.5/35.5 16/40 18/44 20/49 21.5/53.5 23.5/58
  17 String 18 String 19 String 20 String 21 String 22 String 23 String 24 String
3kVA 262/640 283/692 302/750 323/790 345/850 365/900 387/955 408/101.5
6kVA 106/262 115/285 123/302 132/324 140/345 149/365 157/388 167/408
9kVA 63/154 68/167 73/179 78/191 83/204 88/210 93/229 98/242
12kVA 43/106 46.5/115 50/123 53.5/132 57/140 60/149 64/157 68/167
15kVA 32.5/79.5 35/86 37.5*92 40/98 425/105 45/111 48/118 51/124
18kVA 25.5/63 27.5/68 29.5/73 31.5/78 33.5/83 35.5/88 38/93 40/98

Runtime Chart (full load / half load) Universal Module ASY-0674
Load (VA) Number of Strings (2 battery modules per string)
  1 String 2 String 3 String 4 String 5 String 6 String 7 String 8 String
3kVA 8/24 24/59 43/95 58/140 80/175 95/215 119/240 135/290
6kVA   8/24 16/40 24/59 32/83 40/103 49/114 58/140
9kVA     8/24 13/35 18/46 24/59 29/63 35/86
12kVA       8/24 13/33 16/40 19.5/43.5 24/59
15kVA         8/24 11.5/31 14.5/31.5 18/49
18kVA           8/24 11/31.5 13/36
  9 String 10 String 11 String 12 String 13 String 14 String 15 String 16 String
3kVA 155/335 165/365 200/395 215/450 225/500 245/540 270/600 290/620
6kVA 69/156 83/175 90/190 103/205 113/335 123/255 135/273 143/290
9kVA 40/103 46/155 54/125 58/140 63/150 73/165 80/178 86/190
12kVA 29/70 33/80 36/90 41/100 47/100 52/121 56/130 58/140
15kVA 20.5/51 24/58 28/66 31/73 34/83 38/94 41.5/103 44.5/113
18kVA 15.5/41 18/45 20.5/51 24/58 34/83 38/94 41.5/103 44.5/113
  17 String 18 String 19 String 20 String 21 String 22 String 23 String 24 String
3kVA 315/650 335/690 350/720 365/780 375/850 395/890 425/920 450/950
6kVA 148/315 156/333 165/350 175/365 183/385 190/395 198/420 205/440
9kVA 63/200 100/210 107/225 115/240 121/255 125/270 135/280 143/290
12kVA 65/147 70/156 75/165 70/175 85/185 90/195 95/2058 100/215
15kVA 46.5/117 51/127 56/130 58/140 61/149 66/158 71/165 73/170
18kVA 38/94 41/100 44/105 45/115 48/122 54/131 57/137 58/140
Battery strings above and to the right of the dark line require additional (N+X) power modules or an auxiliary charger. Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc. Additional battery runtimes available up to 8 hrs. Please contact your Powerware representative.

Custom Applications - Contact MajorPower.Com
 
Visa MasterCard American Express Accepted     Email This Page | Print Page | Terms & Conditions | About MajorPower.Com | Home
sales@majorpower.com
copyright 2002