| Powerware 9170+ UPS |
|
|
The 9170+ enables customers to "build" a power solution specific to their needs, with an expandable level of redundancy and increased run times through plug-andplay 3 kVA UPS and battery modules. The 9170+ can be configured to fit three-, six-, nine- or twelve-slot enclosures, and is available for rack-mount applications.
The 9170+ also features a new "power-saver" high efficiency mode, a user-selectable feature that increases unit efficiency from 88% in normal operating mode to 97% in Power Saver mode. The combination of its low initial investment, double conversion online technology, ABM, and new highefficiency power-saver mode, means you never have to compromise reliability for efficiency. Unique to the 9170+ is its global deployment capability. By using a high frequency design, housing both logic and power in the power module, andoffering a single cabinet design, distributors and purchasing departments around the world will have fewer system components to contend with, regardless of where the system is deployed.
|
|
  |
|
 |
- Maximum Performance
- The lowest overall cost of ownership is a direct result of the low initial investment, higher operating efficiencies and programmable high efficiency
- A UPS solution that is as easy to install and operate as a PC. Universal components fit in any order in any slot without affecting the operation of the system or its protection of the critical load
- Featuring user-friendly LCD display and two internal communication slots, which accept a wide variety of connectivity devices and the new SNMP/Web adapter card
- Lightweight, high-performance power and battery modules weigh under 30 lbs. for easy service and hot swapping
- Maximum Reliability
- N+X power and logic redundancy eliminates single point-of-failure providing highest reliability and availability
- Redundant modularity virtually eliminates downtime and enhances serviceability
- ABM doubles battery service life
- Maximum Availability
- Double conversion online technology is universally recognized as providing the highest availability in an internetcentric global marketplace
- Provides protection against power surges, spikes, sags, line noise, and lightning
- Maximum Service Plans
- Powerware Gold Plan Plus Enhance and extend your standard UPS warranty with added assurance of knowing your UPS is installed and operated properly from the start
- Comprehensive coverage for the entire UPS
- On-site start-up by authorized Powerware Representative
- Replacement UPS or module delivered to your locations
- Original UPS or module picked up from your locations
- Maximum Flexibility
- Modular design delivers scalable flexible solutions to constantly changing equipment requirements
- Easily expanded by installing additional power, charger, or battery modules to support additional critical applications and devices
- Internal Options: galvanic isolation, line cord, receptacles, communications
- External options: Rack-mount kit, casters (standard on 9- and 12-slot enclosures), extended runtime battery cabinets (housing up to 8 hours of additional runtime), wall-mounted maintenance bypass cabinets
|
|
 |
| General |
| Topology |
True online, double-conversion |
| Diagnostics |
Full system self-test on power up |
| UPS Bypass |
Automatic on overload or UPS failure |
| Environmental And Safety |
| Safety Markings |
UL, CUL |
| EMC Markings |
FCC class A |
| Surge Suppression |
IEEE/ANSI C62.41 |
| Audible Noise |
<50dBA |
| Ambient Operating |
0 to 40ºC (32 to 104ºF) |
| Storage Temperature |
-20 to 40ºC (60ºC w/o batt); -4 to 104ºF (140º F w/o batt) |
| Relative Humidity |
5% to 95%, non-condensing |
| REPO Port |
Meets NEC code 645-11 intent and UL requirements |
| Battery |
| Internal Battery Type |
Sealed, lead-acid; maintenance free |
| Battery Replacement |
Hot-swappable |
| Recharge Time |
<4 hours standard |
| Electrical Input |
| Voltage |
208-240V or 200/100, 208/120, 220/110,240/120 Vac |
| Voltage Range |
176-276V |
| Input Power Factor |
.98 |
| Frequency |
50/60 Hz (±3 Hz) |
| Electrical Output |
| On Utility Voltage Regulation |
±3% of nominal |
| On Battery Voltage Regulation |
±3% of nominal |
| Efficiency |
88% normal operation; 97% High performance (optional programmable) |
| Frequency Regulation |
±3 Hz online; ±0.1 Hz on battery |
| Communications |
| LCD Display |
4 x 20 character backlit display, programmable |
| Language Support |
English, French, Spanish and German |
| Communication ports |
RS232, (DB9) (std) |
| Communication slots |
2 Slots (standard) |
| SNMP capability |
SNMP/Web enabled card options |
| Contact Closures |
Relay Card option |
| Emergency Power off (EPO) |
Input for external EPO |
|
|
 |
Model
Number |
Power
Rating |
Input
Connection |
Output
Connection |
Dimensions
HxWxD (in/cm) |
Weight
(lb/kg) |
| UPS Cabinet Enclosures with Hardwire Input and Output Connections |
| 9170+ 3 Slot |
3 KVA |
Hardwired |
Hardwired |
17.8 x 17.0 x 25.5/
45.0 x 43.0 x 65.0 |
66.0/30.0 |
| 9170+ 6 Slot |
3 to 9kVA |
Hardwired |
Hardwired |
31.5 x 17.0 x 25.0/
80.0 x 43.0 x 65.0 |
103.0/47.0 |
| 9170+ 9 Slot |
3 to 18kVA |
Hardwired |
Hardwired |
47.0 x 24.0 x 28.5/
119.5 x 61.0 x 72.5 |
158.0/72.0 |
| 9170+ 12 Slot |
3 to 18kVA |
Hardwired |
Hardwired |
60.8 x 24.0 x 28.5/
154.0 x 61.0 x 72.5 |
196.0/89.0 |
| Battery Cabinet Enclosures |
| 6 Slot Battery Cabinet |
- |
DC Interconnect Option
ASY-0525 Required |
- |
17.8 x 17.0 x 25.5/
45.0 x 43.0 x 65.0 |
93.0/42.2 |
| 9 Slot Battery Cabinet |
- |
DC Interconnect Option
ASY-0525 Required |
- |
47.0 x 24.0 x 28.5/
119.5 x 61.0 x 72.5 |
148.0/67.1 |
| 12 Slot Battery Cabinet |
- |
DC Interconnect Option
ASY-0525 Required |
- |
60.8 x 24.0 x 28.5/
154.0 x 61.0 x 72.5 |
186.0/84.4 |
| Available Modules |
| Split Phase Power Module |
3 kVA/2.5kw |
- |
- |
4.2 x 14.1 x 15.3/
10.6 x 35.8 x 38.9 |
17.0/7.7 |
| Universal Power Module |
3 kVA/2.5kw |
- |
- |
4.2 x 14.1 x 15.3/
10.6 x 35.8 x 38.9 |
17.0/7.7 |
| Battery Module |
- |
- |
- |
4.2 x 7.0 x 14.8/
10.6 x 17.8 x 37.6 |
30.0/13.6 |
| 20 Amp Charger Module |
3kVA |
- |
- |
4.2 x 14.1 x 15.3/
10.6 x 35.8 x 38.9 |
17.0/7.7 |
|
Notes: 50/60 Hz automatic frequency selection. Input/Output voltages 208-240 V or100/200,120/208, 127/220, 110/220 and 120/240 V. Split phase power Module offer both high and low output voltage. Universal Power Module offers only high output voltage. (3) and (6) slot enclosure dimensions include caster kit.
|
|
|
 |
Runtime Chart (full load / half load) Split-Phase Module ASY-0673
Load (VA) Number of Strings (2 battery modules per string) |
| |
1 String |
2 String |
3 String |
4 String |
5 String |
6 String |
7 String |
8 String |
| 3kVA |
6.5/16 |
16/40 |
27.5/67.5 |
40/98 |
53.5/132 |
67.5/167 |
83/204 |
98/242 |
| 6kVA |
|
6.5/16 |
11/27.5 |
16/40 |
21.5/53.5 |
27.5/68 |
33.5/83 |
40/98 |
| 9kVA |
|
|
65/16 |
9.5/23.5 |
13/31.5 |
16/40 |
20/49 |
23.5/58 |
| 12kVA |
|
|
|
6.5/16 |
9/21.5 |
11/27.5 |
13.5/33.5 |
16/40 |
| 15kVA |
|
|
|
|
6.5/16 |
8/20.5 |
10/25 |
12/30 |
| 18kVA |
|
|
|
|
|
6.5/16 |
8/20 |
9.5/23.5 |
| |
9 String |
10 String |
11 String |
12 String |
13 String |
14 String |
15 String |
16 String |
| 3kVA |
15/283 |
132.324 |
149/365 |
167/408 |
185/456 |
204/501 |
223/549 |
242/595 |
| 6kVA |
46.5/15 |
53.5/132 |
60.5/149 |
575/167 |
75/85 |
83/204 |
90/223 |
98/242 |
| 9kVA |
27.5/67.5 |
31.5/78 |
35.5/88 |
40/98 |
44/109 |
49/120 |
535/132 |
58/143 |
| 12kVA |
19/46.5 |
21.5/53.5 |
24.5/60.5 |
27.5/68 |
30.5/75 |
33.5/83 |
37/90 |
40/98 |
| 15kVA |
14/35 |
16/40 |
18.5/45 |
20.5/50.5 |
23/56 |
25/62 |
27.5/67.5 |
30/73.5 |
| 18kVA |
11/27.5 |
18/44 |
14.5/35.5 |
16/40 |
18/44 |
20/49 |
21.5/53.5 |
23.5/58 |
| |
17 String |
18 String |
19 String |
20 String |
21 String |
22 String |
23 String |
24 String |
| 3kVA |
262/640 |
283/692 |
302/750 |
323/790 |
345/850 |
365/900 |
387/955 |
408/101.5 |
| 6kVA |
106/262 |
115/285 |
123/302 |
132/324 |
140/345 |
149/365 |
157/388 |
167/408 |
| 9kVA |
63/154 |
68/167 |
73/179 |
78/191 |
83/204 |
88/210 |
93/229 |
98/242 |
| 12kVA |
43/106 |
46.5/115 |
50/123 |
53.5/132 |
57/140 |
60/149 |
64/157 |
68/167 |
| 15kVA |
32.5/79.5 |
35/86 |
37.5*92 |
40/98 |
425/105 |
45/111 |
48/118 |
51/124 |
| 18kVA |
25.5/63 |
27.5/68 |
29.5/73 |
31.5/78 |
33.5/83 |
35.5/88 |
38/93 |
40/98 |
Runtime Chart (full load / half load) Universal Module ASY-0674
Load (VA) Number of Strings (2 battery modules per string) |
| |
1 String |
2 String |
3 String |
4 String |
5 String |
6 String |
7 String |
8 String |
| 3kVA |
8/24 |
24/59 |
43/95 |
58/140 |
80/175 |
95/215 |
119/240 |
135/290 |
| 6kVA |
|
8/24 |
16/40 |
24/59 |
32/83 |
40/103 |
49/114 |
58/140 |
| 9kVA |
|
|
8/24 |
13/35 |
18/46 |
24/59 |
29/63 |
35/86 |
| 12kVA |
|
|
|
8/24 |
13/33 |
16/40 |
19.5/43.5 |
24/59 |
| 15kVA |
|
|
|
|
8/24 |
11.5/31 |
14.5/31.5 |
18/49 |
| 18kVA |
|
|
|
|
|
8/24 |
11/31.5 |
13/36 |
| |
9 String |
10 String |
11 String |
12 String |
13 String |
14 String |
15 String |
16 String |
| 3kVA |
155/335 |
165/365 |
200/395 |
215/450 |
225/500 |
245/540 |
270/600 |
290/620 |
| 6kVA |
69/156 |
83/175 |
90/190 |
103/205 |
113/335 |
123/255 |
135/273 |
143/290 |
| 9kVA |
40/103 |
46/155 |
54/125 |
58/140 |
63/150 |
73/165 |
80/178 |
86/190 |
| 12kVA |
29/70 |
33/80 |
36/90 |
41/100 |
47/100 |
52/121 |
56/130 |
58/140 |
| 15kVA |
20.5/51 |
24/58 |
28/66 |
31/73 |
34/83 |
38/94 |
41.5/103 |
44.5/113 |
| 18kVA |
15.5/41 |
18/45 |
20.5/51 |
24/58 |
34/83 |
38/94 |
41.5/103 |
44.5/113 |
| |
17 String |
18 String |
19 String |
20 String |
21 String |
22 String |
23 String |
24 String |
| 3kVA |
315/650 |
335/690 |
350/720 |
365/780 |
375/850 |
395/890 |
425/920 |
450/950 |
| 6kVA |
148/315 |
156/333 |
165/350 |
175/365 |
183/385 |
190/395 |
198/420 |
205/440 |
| 9kVA |
63/200 |
100/210 |
107/225 |
115/240 |
121/255 |
125/270 |
135/280 |
143/290 |
| 12kVA |
65/147 |
70/156 |
75/165 |
70/175 |
85/185 |
90/195 |
95/2058 |
100/215 |
| 15kVA |
46.5/117 |
51/127 |
56/130 |
58/140 |
61/149 |
66/158 |
71/165 |
73/170 |
| 18kVA |
38/94 |
41/100 |
44/105 |
45/115 |
48/122 |
54/131 |
57/137 |
58/140 |
| Battery strings above and to the right of the dark line require additional (N+X) power modules or an auxiliary charger. Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc. Additional battery runtimes available up to 8 hrs. Please contact your Powerware representative. |
|
|
|
|
| Custom Applications - Contact MajorPower.Com |
| |