| MajorBCD 600 Series |
|
|
MajorBCD600
The MajorBCD600 has an all new single board design that incorporates state-of-the-art switchmode technology for unmatched efficiency and ultra-quiet operation.
Multiple stages of filtering reduce radiated or conducted noise to very low levels. The two-stage charging profile charges the batteries at a constant current equal to the maximum continuous output of the unit. When the battery voltages come up to the float voltage that the unit is set to, the current into the batteries will taper off as necessary to maintain the batteries at the float voltage.
The MajorBCD600 can be left permanently connected without fear of overcharge or damage to the batteries. The adjustable float voltage feature allows the unit to be used for any type of battery including lead acid and gel cell.
|
|
 |
 |
| |
 |
MajorBCD600 Specs |
 |
| |
MajorBCD600-32-12 |
| MajorBCD600-32-24 |
|
 |
- Adjustable Output Voltage
- For charging standard or deep cycle lead-acid, VRLA or Gel cell type battery
- Audible & Visual Indicators
- For constant current, low input voltage, low output voltage & over-temperature
- Extremely Rugged
- Well suited for marine and other demanding environments
- High Tolerance
- Ultra-Quiet
|
- Protection
- Current limiting protection
- Short circuit protection
- Reverse input protection
- Output over-voltage crowbar
- Over temperature shutdown
- Spark-Free Connection
- Can be left Permanently Connected
- Dry Contact Output Fail Relay
- Warranty
|
|
|
 |
| Mechanical & Environmental |
| Operating Temperature Range |
0 - 40°C @ Maximum Output |
| Humidity |
0 - 95°C @ Relative Humidity (non-condensing) with optional conformal coating |
| Audible Noise |
None Ødb @ 3 feet |
| Typical Service Life |
>10 years (87,600 hours) |
| Isolation |
Input-Case & Input-Output 1500 VDC; Output-Case 500 VDC |
| Dimensions (L x W x H) |
9.1 x 7.8 x 4.3 in / 23.1 x 19.8 x 10.8 cm |
| Clearance |
1 inch (2.5 cm) all around |
| Physical |
Marine-grade aluminum material, Black anodize / powder epoxy coat finish; 18-8 stainless steel fastenings; 4 contact output terminals |
| Weight |
4.0 lbs / 1.8 kg |
| Warranty |
3 years |
| Safety |
CSA/UL Pending |
|
|
 |
| Model |
MajorBCD600-32-12 |
MajorBCD600-32-24 |
| Input Volts |
20 - 45 |
30 - 45 |
| Input Amps |
40 |
40 |
| Output Volts |
13.6 ± 0.5 VDC |
27.2 ± 0.5 VDC |
| Charging Amps |
50 |
38 |
| Output Crowbar |
16.0 ± 0.5 VDC |
32.0 ± 1.0 VDC |
| Input Fuses |
AGC 25 Amp x 2 |
AGC 25 Amp x 2 |
| Output Fuses |
AGC 30 Amp x 2 |
AGC 25 Amp x 2 |
| Low Input Voltage Alarm |
10.5 VDC |
10.5 VDC |
| Battery Banks |
1 |
1 |
| Stages |
2 |
2 |
| Battery Size (Amp Hours) |
200 - 300 |
150 - 230 |
| Transient Response |
< 1V for 15 Amp Surge |
< 1V for 15 Amp Surge |
| Efficiency |
> 85% @ Maximum Output |
> 85% @ Maximum Output |
| Duty Cycle |
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day |
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day |
| Line Load Regulation |
< ± 0.5% |
< ± 0.5% |
|
|
|
MajorBCD605
The MajorBCD605 has an all new single board design that incorporates state-of-the-art switchmode technology for unmatched efficiency and ultra-quiet operation.
Applications include charging the compulsory battery on vessel's over 20 meters, temporarily brightening 12 volt headlights or work lights, increasing voltage into an automotive or marine ignition system for hotter spark and/or prevention of failures due to voltage drop during engine start, stabilizing 12V and 24 VDC power systems in marine, automotive or aeronautical environments and more.
|
|
 |
 |
| |
 |
MajorBCD605 Specs |
 |
| |
MajorBCD605-12-12 |
| MajorBCD605-12-24 |
|
 |
- Adjustable Output Voltage
- For charging standard or deep cycle lead-acid, VRLA or Gel cell type battery
- Audible & Visual Indicators
- For constant current, low input voltage, low output voltage & over-temperature
- Extremely Rugged
- Well suited for marine and other demanding environments
- High Tolerance
- Ultra-Quiet
|
- Protection
- Current limiting protection
- Short circuit protection
- Reverse input protection
- Output over-voltage crowbar
- Over temperature shutdown
- Spark-Free Connection
- Can be left Permanently Connected
- Dry Contact Output Fail Relay
- Warranty
|
|
|
 |
| Mechanical & Environmental |
| Operating Temperature Range |
0 - 40°C @ Maximum Output; Derate Linearly 2.5% per °C from 40°C |
| Humidity |
0 - 95°C @ Relative Humidity (non-condensing) with optional conformal coating |
| Audible Noise |
None Ødb @ 3 feet |
| Typical Service Life |
>10 years (87,600 hours) |
| Isolation |
Any Input or Output to Case 500 VDC; Input to Output Common Negative |
| Dimensions (L x W x H) |
9.1 x 7.8 x 2.5 in / 23.1 x 19.8 x 6.4 cm |
| Clearance |
1 inch (2.5 cm) all around |
| Physical |
Marine-grade aluminum material, Black anodize / powder epoxy coat finish; 18-8 stainless steel fastenings; 4 contact output terminals |
| Weight |
4.0 lbs / 1.8 kg |
| Warranty |
3 years |
| Safety |
CSA/UL Pending |
|
|
 |
| Model |
MajorBCD605-12-12 |
MajorBCD605-12-24 |
| Input Volts |
10.5 - 14 |
10.5 - 28 |
| Input Amps |
50 |
350 |
| Output Volts |
13.6 ± 0.5 VDC |
27.2 ± 0.5 VDC |
| Charging Amps |
42 |
21 |
| Output Crowbar |
16.0 ± 0.5 VDC |
32.0 ± 1.0 VDC |
| Input Fuses |
AGC 30 Amp x 2 |
AGC 30 Amp x 2 |
| Output Fuses |
AGC 25 Amp x 2 |
AGC 25 Amp x 2 |
| Low Input Voltage Alarm |
10.5 VDC |
10.5 VDC |
| Low Output Voltage Alarm |
Programmed Output Voltage -2.5 VDC |
Programmed Output Voltage -2.5 VDC |
| Battery Banks |
1 |
1 |
| Stages |
2 |
2 |
| Battery Size (Amp Hours) |
168 - 252 |
84 - 126 |
| Transient Response |
< 1V for 15 Amp Surge |
< 1V for 15 Amp Surge |
| Efficiency |
> 85% @ Maximum Output |
> 85% @ Maximum Output |
| Duty Cycle |
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day |
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day |
| Line Load Regulation |
< ± 0.5% |
< ± 0.5% |
|
|
|
MajorBCD610
The MajorBCD610 Battery Charger charges either 12, 24, 32 or 48 Volt batteries from a -48, 72, 110, 220 or 300 VDC power source. Other battery voltages up to 72 Volts are also available by special order.
The all new Current Mode switching design offers increased power and reliability in a compact package. Extra input and output filtering reduce EMI to extremely low levels.
The output voltage is easily adjusted 0.5 Volts above or below the standard output voltage to accommodate special charging requirements. 1 or 2 high quality analog meters can be added (factory option) to allow monitoring of charging current and charging voltage.
|
|
 |
 |
| |
 |
MajorBCD610 Specs |
 |
| |
MajorBCD610-110-12 |
| MajorBCD610-110-24 |
|
 |
- Transient Voltage Suppressor
- Fully Isolated Design
- Adjustable Output Voltage
- For charging standard or deep cycle lead-acid, VRLA or Gel cell type battery
- Audible & Visual Indicators
- For constant current, low input voltage, low output voltage & over-temperature
- Extremely Rugged
- Well suited for marine and other demanding environments
- Short Circuit Shutdown
- User-Selectable 2 or 3 Stage Charging Profile
- High Tolerance
|
- Ultra-Quiet
- Protection
- Current limiting protection
- Short circuit protection
- Reverse input protection
- Output over-voltage crowbar
- Over temperature shutdown
- Spark-Free Connection
- Can be left Permanently Connected
- Dry Contact Output Fail Relay
- Warranty
|
|
|
 |
| Mechanical & Environmental |
| Operating Temperature Range |
0 - 40°C @ Maximum Output; Derate Linearly 2.5% per °C from 40°C |
| Humidity |
0 - 95°C @ Relative Humidity (non-condensing) with optional conformal coating |
| Audible Noise |
None Ødb @ 3 feet |
| Typical Service Life |
>10 years (87,600 hours) |
| Isolation |
Input-Case & Input-Output 1500 VDC; Output-Case 500 VDC |
| Dimensions (L x W x H) |
14.5 x 9.9 x 3.0 in / 36.8 x 25.1 x 7.6 cm |
| Clearance |
1 inch (2.5 cm) all around |
| Physical |
Marine-grade aluminum material, Black anodize / powder epoxy coat finish; 18-8 stainless steel fastenings; 4 contact output terminals |
| Weight |
7.6 lbs / 3.3 kg |
| Warranty |
3 years |
| Safety |
CSA/UL Pending |
|
|
 |
| MajorBCD |
610-48 |
610-72 |
610-100 |
610-250 |
610-300 |
| Nominal Input |
110 |
250 |
300 |
250 |
300 |
| Input Voltage |
100 - 140 |
230 - 280 |
280 - 360 |
230 - 280 |
280 - 360 |
| Input Amps |
3.4 |
1.5 |
1.3 |
1.5 |
1.3 |
| Input Fuse (MDA) |
4 |
3 |
2 |
3 |
2 |
| Noise on Input |
< 25 mV |
< 25 mV |
< 25 mV |
< 25 mV |
< 25 mV |
| Nominal Output Voltage |
12 |
24 |
32 |
48 |
| Output Voltage |
13.6 ± 0.05 |
27.2 ± 0.05 |
36.3 ± 0.05 |
54.4 ± 0.05 |
| Absorption Voltage |
14.4 |
28.8 |
38.4 |
57.6 |
| Charging Amps |
40 |
20 |
15 |
10 |
| Absorption to Float |
4.0 Amps |
2.0 Amps |
1.5 Amps |
1.0 Amps |
| Output Fuses (ATC) |
ATC 40 x 2 |
ATC 30 x 2 |
ATC 20 x 2 |
ATC 15 x 2 |
| Battery Banks |
1 or 2 |
1 or 2 |
1 or 2 |
1 or 2 |
| Output Adjustment |
± 0.5 |
± 0.5 |
± 0.5 |
± 0.5 |
| Battery Size (AH) |
160 - 240 |
80 - 120 |
60 - 90 |
40 - 60 |
| Output Crowbar |
16.0 ± 0.5 V |
32.0 ± 1.0 V |
42.7 ± 1.3 V |
63.9 ± 2.0 V |
| Output Ripple & Noise |
< 50 mV |
< 50 mV |
< 50 mV |
< 50 mV |
| Transient Response |
< 2 V for 50% Surge |
< 2 V for 50% Surge |
< 2 V for 50% Surge |
< 2 V for 50% Surge |
| Line Load Regulation |
< ± 0.5% |
< ± 0.5% |
< ± 0.5% |
< ± 0.5% |
| Duty Cycle |
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day
|
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day |
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day |
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day |
| Efficiency |
> 75% @ Maximum Output |
> 75% @ Maximum Output |
> 75% @ Maximum Output |
> 75% @ Maximum Output |
| Stages |
2 or 3 |
2 or 3 |
2 or 3 |
2 or 3 |
|
|
| Custom DC Battery Charger Application - Contact MajorPower.Com |
| |