MajorBCA 32 Volt Marine Battery Chargers
7.5 - 30 Amps
|
|
|
MajorBCA310
MajorBCA310 32 Volt Battery Chargers are marine-grade, adjustable units ideal for charging standard, deep cycle lead-acid, VRLA, or gel type batteries. These ultra-quiet units can be left permanently connected. Multiple stages of filtering reduce radiated or conducted noise to very low levels.
Extra features include adjustable output voltage, audible and visual indicators for low input voltage, low output voltage and over temperature. Safety features include reverse input protection, over-temperature shutdown, current limiting, short circuit protection with automatic recovery, input undervoltage shutdown, reverse battery protection and output overvoltage crowbar.
Optional features include a dry contact alarm relay output, and remote panel monitoring with On/Off control.
|
|
 |
|
|
 |
- Adjustable output voltage for charging standard or deep cycle lead-acid, VRLA or Gel type battery
- User selectable 2 or 3 stage charging profile
- Audible & visual indicators for low input voltage, low output voltage & over- temperature
- Over-temperature shutdown
- Short circuit protection
- Output overvoltage crowbar
- Current limiting
- Ultra-quiet low EMI operation
- Can be left permanently connected
- Dry contact output fail relay
- Remote control option
|
|
 |
MajorBCA310 Specs |
 |
| |
MajorBCA310-110-32 |
| MajorBCA310-220-32 |
| |
|
 |
| Efficiency |
> 75 % @ maximum output |
| Stages |
2 & 3 (user selectable) |
| Temp. Range |
0 - 40o C @ maximum output |
| Isolation |
Input-Case & Input-Output 1500 VDC, Output-Case 500 VDC |
| Dimensions |
9.1 x 7.8 x 2.5 in / 23.1 x 19.8 x 6.4 cm |
| Clearance |
1 Inch (2.5 cm) all around |
| Material |
Marine Grade Aluminum |
| Finish |
Black Powder Epoxy |
| Fastenings |
18-8 Stainless |
| Weight |
4.0 lb / 1.8 kg |
|
|
 |
|
| Nominal (op) |
32 |
| Float (Vdc) |
36.3 ± 0.05 |
| Absorption Voltage (Vdc) |
38.4 |
| Output Adjustment |
± 0.5 |
| Charging Amps |
7.5 |
| Absorption to Float |
0.75 Amps |
| Battery Size (Amp Hours) |
30 - 45 |
| Battery Banks |
1 or 2 |
| Output Crowbar |
42.7 ± 1.3 V |
|
|
|
MajorBCA610
MajorBCA610 32 Volt Battery Chargers are marine-grade, adjustable units ideal for charging standard, deep cycle lead-acid, VRLA, or gel type batteries. These ultra-quiet units can be left permanently connected.
Extra input and output filtering reduce EMI to extremely low levels. Reliability features include an input fuse, thermal shutdown, current limiting, reverse battery hookup protection and output short circuit shutdown with automatic recovery.
The output voltage is easily adjusted 0.5 volts above or below the standard output voltage to accommodate special charging requirements. 1 or 2 high quality analog meters can be added (factory option) to allow monitoring of charging current and charging voltage.
|
|
 |
|
 |
 |
- Adjustable output voltage for charging standard or deep cycle lead-acid, VRLA or Gel type battery
- User selectable 2 or 3 stage charging profile
- Audible & visual indicators for low input voltage, low output voltage & over- temperature
- Over-temperature shutdown
- Short circuit protection
- Output overvoltage crowbar
- Current limiting
- Ultra-quiet low EMI operation
- Can be left permanently connected
- Dry contact output fail relay
- Remote control option
- One or two output ammeter option
- Equalize & temperature compensation option
|
|
 |
MajorBCA610 Specs |
 |
| |
MajorBCA610-110-32 |
| MajorBCA610-220-32 |
| |
|
 |
| Efficiency |
> 75 % @ maximum output |
| Stages |
2 & 3 (user selectable) |
| Temp. Range |
0 - 40o C @ maximum output |
| Isolation |
Input-Case & Input-Output 1500 VDC, Output-Case 500 VDC |
| Dimensions |
14.5 x 9.9 x 3.0 in / 36.8 x 25.1 x 7.6 cm |
| Clearance |
1 Inch (2.5 cm) all around |
| Material |
Marine Grade Aluminum |
| Finish |
Black Powder Epoxy |
| Fastenings |
18-8 Stainless |
| Weight |
7.2 lb / 3.3 kg |
|
|
 |
|
| Nominal (op) |
32 |
| Float (Vdc) |
36.3 ± 0.05 |
| Absorption Voltage (Vdc) |
38.4 |
| Output Adjustment |
± 0.5 |
| Charging Amps |
17 |
| Absorption to Float |
1.7 Amps |
| Battery Size (Amp Hours) |
68 - 102 |
| Battery Banks |
1 or 2 |
| Output Crowbar |
42.7 ± 1.3 V |
|
|
|
MajorBCA1000
MajorBCA1000 32 Volt Battery Chargers are marine-grade, adjustable units ideal for charging standard, deep cycle lead-acid, VRLA, or gel type batteries. These ultra-quiet units can be left permanently connected.
Extra input and output filtering reduce EMI to extremely low levels. Reliability features include an input fuse, thermal shutdown, current limiting, reverse battery hookup protection and output short circuit shutdown with automatic recovery. The output voltage is easily adjusted 0.5 volts above or below the standard output voltage.
The MajorBCA1000 features equalize & temperature compensation, and remote control options. 1 or 2 high quality analog meters can be added (factory option) to allow monitoring of charging current and charging voltage.
|
|
 |
|
 |
 |
- Adjustable output voltage for charging standard or deep cycle lead-acid, VRLA or Gel type battery
- User selectable 2 or 3 stage charging profile
- Audible & visual indicators for low input voltage, low output voltage & over- temperature
- Over-temperature shutdown
- Short circuit protection
- Output overvoltage crowbar
- Current limiting
- Ultra-quiet low EMI operation
- Can be left permanently connected
- Dry contact output fail relay
- Remote control option
- One or two output ammeter option
- Equalize & temperature compensation option
|
|
 |
MajorBCA1000 Specs |
 |
| |
MajorBCA1000-110-32 |
| MajorBCA1000-220-32 |
| |
|
 |
| Efficiency |
> 75 % @ maximum output |
| Stages |
2 & 3 (user selectable) |
| Temp. Range |
0 - 40o C @ maximum output |
| Isolation |
Input-Case & Input-Output 1500 VDC, Output-Case 500 VDC |
| Dimensions |
14.5 x 9.9 x 5.5 in / 36.8 x 25.1 x 14.0 cm |
| Clearance |
1 Inch (2.5 cm) all around |
| Material |
Marine Grade Aluminum |
| Finish |
Black Powder Epoxy |
| Fastenings |
18-8 Stainless |
| Weight |
12 lb / 5.5 kg |
|
|
 |
|
| Nominal (op) |
32 |
| Float (Vdc) |
36.3 ± 0.05 |
| Absorption Voltage (Vdc) |
38.4 |
| Output Adjustment |
± 0.5 |
| Charging Amps |
30 |
| Absorption to Float |
3 Amps |
| Battery Size (Amp Hours) |
120 - 180 |
| Battery Banks |
1 or 2 |
| Output Crowbar |
42.7 ± 1.3 V |
|
|
| Custom Charger Application - Contact MajorPower.Com |
| |