| Telecom Battery Series |
|
| "TELECOM" TL and CSL
Batteries are the ideal choice for Telecommunication applications
which require a reliable, compact and affordable solution. Since these
batteries are low-gassing they require no special ventilation. Additionally,
a compact design makes them perfect for low maintenance and space
restricted applications. |
|
 |
|
 |
|
- Ten-year design life.
- A recognized component of U.L.
- Valve regulated lead acid battery (VRLA).
- Absorbed glass mat technology (AGM) with gas recombination greater
than 99%.
- Operates at a low internal pressure.
- Never needs watering, minimal maintenance.
- 99.7% pure lead calcium grids.
- Shock absorbant thick wall polypropylene cases.
- *Cases are flame retardant, meet U.L. 94. V0 requirements, and have
an oxygen index greater than 28%.
- Cold forged non-porous terminal bushings, eliminate post leakage.
- Thermally welded cover to case bond, eliminates both acid and electrical
leaks.
- Over-sized, through the partition inter-cell welds provide low resistance
connections, with minimal power loss.
- Each cell has a low pressure safety release venting system, recognized
per U.L. 924.
- Measured high vacuum acid fill, reduces electrical variability between
cells.
- 100% recyclable materials.
- Options:
- Terminal covers and custom inter-connecting battery cables. (Terminal
covers are standard on the CSL models).
- **No transport restrictions:
- Surface transport. Classified as non-hazardous material as relates
to DOT-CFR Tile 49 part 171-189.
- Water transport. Classified as non-hazardous materials as per
IMDG amendment 27.
- Air transport. Complies with IATA / ICAO, special provision A67.
|
|
 |
| Operating Temperature Range |
| Discharge |
-40ºF (-40ºC) to +140ºF (60ºC) |
| Charge |
-4ºF (-20ºC) to +122ºF (50ºC) |
| Ideal Operating Temp Range |
+68ºF (20ºC) to +77ºF (25ºC) |
| Charging Voltage |
| Float operation |
2.25 to 2.30 V.P.C. |
| Cycling operation |
2.35 V.P.C. |
| Charge voltage temperature compensation factor |
Temperature correction factor for float voltage charge is to add 1.7mV/ºF (3mV/ºC) below 77ºF (25ºC) and subtract 1.7mV/ºF (3mV/ºC) above 77ºF (25ºC). This correction factor only applies to temperatures between 32ºF (0ºC) and 104ºF (40ºC) |
| Maximum charging currents |
| Partially discharged |
Self limiting |
| 80% to 100% discharge |
C/4 amperes |
| Storage time from a fully charged condition |
6 months at 77ºF (25ºC) (less at higher temperatures) |
|
|
 |
| "Telecom"
Series - Traditional Design |
| Battery Model # |
Volts Nominal |
AH@8 hrs to 1.75VPC |
Dimensions
L x W x H** |
Weight |
| TL-1230 |
12 |
29 |
7.71 x 5.18 x 7.19"
196 x 865 x 183mm |
26.7lbs
(12.1kg) |
| TL-1245 |
12 |
45 |
8.61 x 5.29 x 8.17"
219 x 134 x 208mm |
35.3lbs
(16kg) |
| TL-1270 |
12 |
68 |
10.20 x 6.57 x 9.03"
259 x 167 x 229mm |
60.6lbs
(27.5kg) |
| TL-1280 |
12 |
82 |
12 x 6.57 x 9.21"
305 x 234 x 245mm |
71.9lbs
(32.7kg) |
| TL-1295 |
12 |
96 |
13.54 x 6.76 x 9.02"
344 x 172 x 229mm |
80.6lbs
(36.7kg) |
| TL-12120 |
12 |
118 |
13.54 x 6.76 x 11.02"
344 x 172 x 280mm |
99.4lbs
(45.2kg) |
| TL-6196 |
6 |
193 |
10.71 x 7.38 x 10.93"
272 x 187 x 278mm |
81.5lbs
(37kg) |
| TL-2480 |
2 |
480 |
10.71 x 7.38 x 10.93"
272 x 187 x 278mm |
87lbs
(39.5kg) |
|
|
| "Telecom"
Series - Front Access Design |
| Battery Model # |
Volts Nominal |
AH@8 hrs to 1.75VPC |
Dimensions
L x W x H** |
Weight |
| CSL-1280 |
12 |
82 |
21 x 4.28 x 9.63"
534 x 109 x 245mm |
74lbs
(33.6kg) |
| CSL-12100 |
12 |
100 |
21 x 4.28 x 9.63"
534 x 109 x 245mm |
84lbs
(38.2kg) |
| CSL-12170 |
12 |
170 |
20.9 x 8.7 x 10.1"
534 x 221 x 257mm |
152lbs
(69.1kg) |
|
| |
* All batteries have "L" type lead
terminals except the SLF types which have a drop terminal with copper
insert.
** Height is to the top of the terminal. |
|
|
| Custom